{"id":85,"date":"2010-06-25T22:14:21","date_gmt":"2010-06-25T21:14:21","guid":{"rendered":"http:\/\/www.aed.eu.com:\/aed"},"modified":"2017-08-23T10:29:29","modified_gmt":"2017-08-23T09:29:29","slug":"stobhill","status":"publish","type":"page","link":"https:\/\/www.aed.consulting\/structural-engineers\/portfolio\/stobhill\/","title":{"rendered":"stobhill hospital"},"content":{"rendered":"\n\t\t\t\t\t\n\n\t\t\t\t\t<!-- START UNITE GALLERY 1.7.9 -->\n\t\t\t\t\t\n\t\t\t\t\n\t\t\t<div id='unitegallery_26_1' class='unite-gallery' style='margin:0px auto;margin-bottom:25px;'>\n\t\t\t\t\n\n\t\t\t\t\t\t<img decoding=\"async\" alt=\"stobhill_301x401\"\n\t\t\t\t\t\t     src=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_301x401.jpg\"\n\t\t\t\t\t\t     data-thumb=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_301x401.jpg\"\n\t\t\t\t\t\t     title=\"\"\n\t\t\t\t\t\t     style=\"display:none\">\n\n\t\t\t\t\t\t<img decoding=\"async\" alt=\"stobhill_301x400\"\n\t\t\t\t\t\t     src=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_301x400.jpg\"\n\t\t\t\t\t\t     data-thumb=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_301x400.jpg\"\n\t\t\t\t\t\t     title=\"\"\n\t\t\t\t\t\t     style=\"display:none\">\n\n\t\t\t\t\t\t<img decoding=\"async\" alt=\"stobhill_300x400\"\n\t\t\t\t\t\t     src=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_300x400.jpg\"\n\t\t\t\t\t\t     data-thumb=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_300x400.jpg\"\n\t\t\t\t\t\t     title=\"\"\n\t\t\t\t\t\t     style=\"display:none\">\n\n\t\t\t\t\t\t<img decoding=\"async\" alt=\"stobhill_242x401\"\n\t\t\t\t\t\t     src=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_242x401.jpg\"\n\t\t\t\t\t\t     data-thumb=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_242x401.jpg\"\n\t\t\t\t\t\t     title=\"\"\n\t\t\t\t\t\t     style=\"display:none\">\n\n\t\t\t\t\t\t<img decoding=\"async\" alt=\"stobhill_240x400\"\n\t\t\t\t\t\t     src=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_240x400.jpg\"\n\t\t\t\t\t\t     data-thumb=\"https:\/\/www.aed.consulting\/aed\/wp-content\/uploads\/2015\/09\/stobhill_240x400.jpg\"\n\t\t\t\t\t\t     title=\"\"\n\t\t\t\t\t\t     style=\"display:none\">\n\t\t\t<\/div>\n\n\t\t\t<script type='text\/javascript'>\n\t\t\t\twindow.onload = function(e) {\n\t\t\t\t\tif(typeof ugCheckForErrors == \"undefined\"){\n\t\t\t\t\t\tdocument.getElementById(\"unitegallery_26_1\").innerHTML = \"<span style='color:red'>Unite Gallery Error - gallery js and css files not included in the footer. Please make sure that wp_footer() function is added to your theme.<\/span>\";}\n\t\t\t\t\telse{ ugCheckForErrors(\"unitegallery_26_1\", \"jquery\");}\n\t\t\t\t};\n\t\t\t<\/script>\n\n\t\t\t<!-- END UNITEGALLERY -->\n<p>A new day care hospital in Glasgow, built on poor ground. In addition to the main buildings the project includes a 70m long glazed arcade canopy; a three storey hybrid propped cantilever\/scissor stair; multi-storey glazed screens; link bridges; isolated slabs for medical physics equipment and three external canopies. Design and detailing of all these complex features was undertaken.<\/p>\n<p><b>Design &amp; Health International Academy Awards 2010 &#8211; Best International Project under 40,000 sqm<br \/>\nRIBA Award 2010<br \/>\nPublic Private Finance Awards Best Designed Project 2010<br \/>\nGlasgow Institute of Architects Awards Best Healthcare Building 2009<br \/>\nBuilding Better Healthcare Awards Best Designed Hospital 2009<br \/>\nRoses Design Awards Best of the Best 2009 Grand Prix<br \/>\nRoses Design Awards Best Public Building 2009 Gold<\/b><\/p>\n<p>Project value \u00a3105M<\/p>\n<p class=\"whileat\">(while at SKM)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A new day care hospital in Glasgow, built on poor ground. In addition to the main buildings the project includes a 70m long glazed arcade&#8230;<\/p>\n","protected":false},"author":8889,"featured_media":4685,"parent":5018,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"page-template-fullwidth.php","meta":{"footnotes":""},"categories":[129],"tags":[106,105],"yst_prominent_words":[],"class_list":["post-85","page","type-page","status-publish","has-post-thumbnail","hentry","category-new-build","tag-atrium","tag-glass"],"_links":{"self":[{"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/pages\/85","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/users\/8889"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/comments?post=85"}],"version-history":[{"count":0,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/pages\/85\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/pages\/5018"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/media\/4685"}],"wp:attachment":[{"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/media?parent=85"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/categories?post=85"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/tags?post=85"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/www.aed.consulting\/structural-engineers\/wp-json\/wp\/v2\/yst_prominent_words?post=85"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}